Comparative Diagnostic Accuracy of Clinical Pallor at Different Anatomical Sites for Detecting Anemia in Pregnant Women Using HemoCue® as the Reference Standard
Jegadeesan, Dhivagar and Rajendran, Vijaykumar and Saranya, Rajamanickam (2026) Comparative Diagnostic Accuracy of Clinical Pallor at Different Anatomical Sites for Detecting Anemia in Pregnant Women Using HemoCue® as the Reference Standard. Cureus. ISSN 2168-8184
pdf 02.pdf - Published Version
Download (1MB)
Abstract
Background
Anemia during pregnancy remains a major public health problem in low-resource settings. Although
hemoglobin estimation using portable devices such as the HemoCue® Hb 201 System (HemoCue AB,
Ängelholm, Sweden) is reliable, clinical assessment of pallor continues to be widely used in primary care
because of its simplicity, feasibility, and low cost. However, evidence comparing the diagnostic accuracy of
pallor at different anatomical sites among pregnant women is limited.
Objective
This study aimed to determine and compare the diagnostic accuracy of clinical pallor at different anatomical
sites for detecting anemia among pregnant women using HemoCue® hemoglobin estimation as the
reference standard.
Methods
A cross-sectional diagnostic accuracy study was conducted among 186 pregnant women attending the Rural
Health Training Centre (RHTC) in Barwala, Delhi. Clinical pallor was assessed under natural light at the
palpebral conjunctiva, nail bed, palm, and palmar crease. Hemoglobin concentration was measured using
HemoCue® as the reference standard. Diagnostic accuracy measures, including sensitivity, specificity,
positive predictive value (PPV), negative predictive value (NPV), likelihood ratios, and Cohen's kappa (κ),
were calculated for detecting anemia (hemoglobin <11 g/dL).
Results
Among the 186 pregnant women enrolled, 139 (74.7%) were anemic based on HemoCue® hemoglobin
estimation. Palpebral conjunctival pallor demonstrated the highest sensitivity (98.6%) and specificity
(93.6%), with excellent agreement (κ = 0.92). Nail bed pallor showed a sensitivity of 81.3% and a specificity
of 42.6%, while palmar pallor demonstrated a sensitivity of 71.9% and a specificity of 78.7%. Palmar crease
pallor had the lowest sensitivity (46.0%) but a specificity of 78.7%. Palpebral conjunctival pallor also showed
the highest positive LR (LR+; 15.45) and the lowest negative LR(LR-; 0.02).
Conclusion
Palpebral conjunctival pallor demonstrated the highest diagnostic accuracy for detecting anemia in pregnant
women and may serve as a reliable screening method in primary care settings where hemoglobin estimation
is unavailable. Palm and palmar crease examination may provide complementary clinical information but
are less accurate than conjunctival assessment.
| Item Type: | Article |
|---|---|
| Subjects: | R Medicine > R Medicine (General) |
| Divisions: | Faculty of Medicine, Health and Life Sciences > School of Medicine |
| Depositing User: | Unnamed user with email techsupport@mosys.org |
| Date Deposited: | 04 Nov 2026 09:49 |
| Last Modified: | 04 Nov 2026 09:49 |
| URI: | https://ir.svmchri.ac.in/id/eprint/27 |